Chat with Sunniva on WhatsApp
Skip to Content

Products › Sunniva Home Split › 200 L

Sunniva Home · Split · SE-HS-200

Sunniva Home Split 200

A 200 L enamel-lined tank indoors and a quiet outdoor unit outside, joined by an insulated copper pipe up to 2.5 m long. Best for a family of 3–4. Hot water up to 60 °C on the heat pump alone, for up to 75% less electricity than an electric geyser.

MRP

₹1,04,900

Includes 18% GST and delivery to any pin code. ₹88,898 basic + ₹16,002 GST; business buyers claim the GST back.

Datasheet (PDF)

Pre-order online or on WhatsApp now. Deliveries start in early 2027, and you can cancel free any time before dispatch.

One price for everyoneInstallation from ₹3,0005-yr tank · 5-yr compressor · 3-yr full warranty
Sunniva Home Split 200: outdoor unit and enamel-lined tank
Outdoor unit outside, enamel-lined tank indoors.
Tank200 L
Heating capacity3.5 kW
Power input870 W
COP4.0
Noise (outdoor)≤ 42 dB(A)
Hot waterUp to 60 °C

Choose the size

Allow about 40–60 litres of hot water per person per day. Not sure? Tell us your family size and bathrooms on WhatsApp.

Specifications

Tank capacity200 L
Heating capacity3.5 kW
Rated power input870 W
COP*4.0
Running current4.0 A
Hot water55 °C rated, up to 60 °C on the heat pump, 75 °C with backup heater
Outdoor air range−7 °C to 43 °C
Refrigerant / compressorR410A · GMCC rotary
Noise (outdoor unit)≤ 42 dB(A)
Outdoor unit (W×D×H), weight766×268×550 mm, 28 kg
Tank (Ø×H), weight510×1,710 mm, 68 kg
Water connectionsDN15
Heat exchangerMicro-channel coil wrapped outside the enamel-lined steel tank
Backup heater2 kW with thermostat
Power supply220–240 V / 50 Hz / 1 ph, Class I, IPX4
Basic price₹88,898
GST (18%), claimable for business use₹16,002
Price incl. GST and delivery₹1,04,900

*Rated at outdoor air 20 °C (wet bulb 15 °C), water heated from 15 °C to 55 °C. Specifications may change without notice.

Functions, features and benefits

Touch controller with key lock

Set the water anywhere from 20 to 60 °C on a backlit touch panel. The keys lock themselves when the unit is idle.

Children and guests can’t change your settings by accident
Two daily heating timers

A built-in clock and two programmable heating windows a day.

Heat in off-peak tariff hours, or just before the morning rush
Backup heater that switches itself in

The 2 kW heater starts automatically below an outdoor temperature your installer sets.

Hot water stays reliable through the coldest spells
Automatic defrost

When frost builds on the outdoor coil in winter, the unit clears it briefly and goes back to heating.

Full output on cold mornings with nothing for you to do
Frost protection on standby

Below 5 °C outside, the unit runs itself to keep the water moving and heats the tank to 12 °C if it nears freezing.

No frozen tank or burst pipes in hill stations
Quiet in warm weather

Above 26 °C outside the fan drops to low speed.

Quieter running on summer nights, when you need the least heat
Self-diagnosis with fault codes

Live readings of water, coil, gas and air temperatures, and a clear code if anything goes wrong.

Our technician knows the fault before reaching you, so most fixes take one visit
Protection built in

High- and low-pressure switches, discharge-temperature and compressor over-current protection.

The system shuts down safely before anything can be damaged
Enamel-lined tank, 50 mm insulation

Blue-crystal enamel lining resists corrosion and scale; thick foam keeps water hot for hours.

Longer tank life and hot water left over from yesterday’s heating

How it works

How a Sunniva split heat pump heats water The outdoor unit collects heat from the air; refrigerant gas carries it indoors to the cylinder. OUTDOOR UNIT INDOOR CYLINDER 55°C 1 2 3 4 5 6 1 Air in The fan pulls outdoor air through the finned coil. Even at −7 °C it still holds useful heat. 2 Evaporator Cold refrigerant in the coil soaks up that heat and boils into a vapour. 3 Compressor The GMCC rotary compressor squeezes the vapour into a hot, high-pressure gas. 6 Expansion valve Back outdoors, the liquid's pressure drops; it turns cold and the cycle repeats. 4 Hot gas travels indoors Through insulated copper pipe, up to 2.5 m. No water pipes run through the wall. Cool air out The fan blows the chilled air away from the unit. 5 Micro-channel exchanger Gas circulates through flat aluminium micro-channels bonded to the outside of the tank, heats the water through the steel wall and condenses back to a liquid. Hot water out Up to 60 °C on the heat pump alone. Electric back-up Takes the water to 75 °C when it is wanted. Cold water in Mains water enters at the bottom. Hot refrigerant gas Liquid refrigerant Low-pressure vapour Sealed R410A loop: the refrigerant never touches the water.
  1. Air in. The outdoor fan pulls air through the finned coil; even at −7 °C it holds useful heat.
  2. Evaporator. Cold refrigerant soaks up that heat and boils into a vapour.
  3. Compressor. The GMCC rotary compressor turns the vapour into a hot, high-pressure gas.
  4. Hot gas travels indoors. Through insulated copper pipe, up to 2.5 m. No water pipes run through the wall.
  5. Micro-channel exchanger. The gas circulates through flat aluminium micro-channels bonded to the outside of the tank, heats the water through the steel wall and condenses to a liquid.
  6. Expansion valve. Back outdoors the liquid's pressure drops, it turns cold and the cycle repeats.

Installation

A fixed charge by city, the same for every model. Installed by Sunniva or an authorised partner.

Metro cities₹3,000Mumbai, Thane, Pune, Delhi, Bengaluru, Hyderabad, Chennai, Kolkata, Ahmedabad
Tier 2 cities₹5,000About 90 cities, such as Jaipur, Lucknow, Surat, Nagpur, Nashik, Kochi, Indore, Coimbatore, Gurugram, Noida
Rest of India₹6,000Every other pin code

One fixed charge per unit for standard installation, the same for every model. City tiers follow the Government of India city classification. Extras listed below are quoted separately.

Sunniva Home Split: site installation schematicIndicative hookup. Confirm the final scheme against the installation manual and local plumbing code.WALLOUTDOOR (balcony / terrace)INDOOR (utility / bathroom area)Outdoor heat pump unit12345Enamel-lined tank, 200 / 300 / 500 L655°C7891011Mains12to floor drain13Taps14MCB+ earth151Outdoor unit: keep the coil and fan clear (see manual)2Wall bracket or stand, level, anti-vibration pads3Condensate drain from the base tray4Service valves on the outdoor unit5Insulated copper gas + liquid lines, up to 2.5 m6Wired controller on the tank7Micro-channel coil wrapped outside the tank8Isolation valve on the mains feed9Y-strainer10Pressure-reducing valve if mains exceeds the tank rating11Non-return valve12Safety valve (supplied); pipe to a drain, never cap it13Isolation valve on the hot outlet14Drain valve at the tank base15Dedicated MCB and earthing, unit and backup heaterRefrigerant gasLiquid / cold waterHot waterPower

Standard installation includes

  • Outdoor unit on a wall bracket or stand, like an AC
  • Insulated copper pipe between outdoor unit and tank, up to 2.5 m
  • Tank connected to your existing plumbing within 2 m
  • Safety valve and drain piped, commissioning and a demonstration

Quoted separately

Extra copper pipe per metre, a stand or plinth, a new MCB or cable run, and removing an old geyser are quoted separately.

Looking after it

  • Every 6 months: Check the magnesium anode and replace it when used up; clean the tank
  • Every year: Operate the safety valve lever and clean the outdoor coil of dust
  • Before a long break: Switch off, drain the tank in freezing areas, and close the valves

Warranty

  • 5 years on the enamel-lined tank
  • 5 years on the compressor
  • 3 years on the whole unit, parts and labour

Register online within 30 days. Installed by Sunniva or an authorised partner, used within the water-quality limits, and the magnesium anode checked every 6 months.

Buying for a business?

Send your GSTIN with your order and we issue a GST invoice in your company name, so you can claim the ₹16,002 GST as input tax credit. Depreciation on the basic price may also apply; your CA confirms eligibility and the rate.

Every Sunniva Home heat pump has one price, the same in every city, for one unit or fifty. See our terms of sale, cancellation and refunds and shipping and installation.

Considering the all-in-one instead?

Prefer a single unit with nothing to fit on a wall?

See Sunniva Home All-in-one →

Common questions

Does it work in winter?

Yes, down to −7 °C outside air, with a 2 kW backup heater for the coldest days.

How much will I save?

About 4 units of heat for every unit of electricity, so up to 75% less power than an electric geyser for the same hot water. Actual savings depend on use, tariff and climate.

Who installs it in my city?

Our own team in our strongest cities, authorised partners elsewhere. Installation is ₹3,000 in metro cities, ₹5,000 in tier 2 cities and ₹6,000 everywhere else; check your pin code in the Installation section.

Where does the outdoor unit go?

On a balcony, terrace or outside wall, like an AC outdoor unit, within 2.5 m of pipe run from the tank. Keep the coil and fan clear of walls and screens.

Can I keep my existing geyser plumbing?

Yes. The tank connects to your existing hot and cold lines; the installer adds a safety valve, non-return valve and drain as shown in the schematic.