Products › Sunniva Home Split › 200 L
Sunniva Home Split 200
A 200 L enamel-lined tank indoors and a quiet outdoor unit outside, joined by an insulated copper pipe up to 2.5 m long. Best for a family of 3–4. Hot water up to 60 °C on the heat pump alone, for up to 75% less electricity than an electric geyser.
MRP
Includes 18% GST and delivery to any pin code. ₹88,898 basic + ₹16,002 GST; business buyers claim the GST back.
Pre-order online or on WhatsApp now. Deliveries start in early 2027, and you can cancel free any time before dispatch.

Choose the size
Allow about 40–60 litres of hot water per person per day. Not sure? Tell us your family size and bathrooms on WhatsApp.
Specifications
| Tank capacity | 200 L |
|---|---|
| Heating capacity | 3.5 kW |
| Rated power input | 870 W |
| COP* | 4.0 |
| Running current | 4.0 A |
| Hot water | 55 °C rated, up to 60 °C on the heat pump, 75 °C with backup heater |
| Outdoor air range | −7 °C to 43 °C |
| Refrigerant / compressor | R410A · GMCC rotary |
| Noise (outdoor unit) | ≤ 42 dB(A) |
| Outdoor unit (W×D×H), weight | 766×268×550 mm, 28 kg |
| Tank (Ø×H), weight | 510×1,710 mm, 68 kg |
| Water connections | DN15 |
| Heat exchanger | Micro-channel coil wrapped outside the enamel-lined steel tank |
| Backup heater | 2 kW with thermostat |
| Power supply | 220–240 V / 50 Hz / 1 ph, Class I, IPX4 |
| Basic price | ₹88,898 |
| GST (18%), claimable for business use | ₹16,002 |
| Price incl. GST and delivery | ₹1,04,900 |
*Rated at outdoor air 20 °C (wet bulb 15 °C), water heated from 15 °C to 55 °C. Specifications may change without notice.
Functions, features and benefits
Set the water anywhere from 20 to 60 °C on a backlit touch panel. The keys lock themselves when the unit is idle.
Children and guests can’t change your settings by accidentA built-in clock and two programmable heating windows a day.
Heat in off-peak tariff hours, or just before the morning rushThe 2 kW heater starts automatically below an outdoor temperature your installer sets.
Hot water stays reliable through the coldest spellsWhen frost builds on the outdoor coil in winter, the unit clears it briefly and goes back to heating.
Full output on cold mornings with nothing for you to doBelow 5 °C outside, the unit runs itself to keep the water moving and heats the tank to 12 °C if it nears freezing.
No frozen tank or burst pipes in hill stationsAbove 26 °C outside the fan drops to low speed.
Quieter running on summer nights, when you need the least heatLive readings of water, coil, gas and air temperatures, and a clear code if anything goes wrong.
Our technician knows the fault before reaching you, so most fixes take one visitHigh- and low-pressure switches, discharge-temperature and compressor over-current protection.
The system shuts down safely before anything can be damagedBlue-crystal enamel lining resists corrosion and scale; thick foam keeps water hot for hours.
Longer tank life and hot water left over from yesterday’s heatingHow it works
- Air in. The outdoor fan pulls air through the finned coil; even at −7 °C it holds useful heat.
- Evaporator. Cold refrigerant soaks up that heat and boils into a vapour.
- Compressor. The GMCC rotary compressor turns the vapour into a hot, high-pressure gas.
- Hot gas travels indoors. Through insulated copper pipe, up to 2.5 m. No water pipes run through the wall.
- Micro-channel exchanger. The gas circulates through flat aluminium micro-channels bonded to the outside of the tank, heats the water through the steel wall and condenses to a liquid.
- Expansion valve. Back outdoors the liquid's pressure drops, it turns cold and the cycle repeats.
Installation
A fixed charge by city, the same for every model. Installed by Sunniva or an authorised partner.
One fixed charge per unit for standard installation, the same for every model. City tiers follow the Government of India city classification. Extras listed below are quoted separately.
Standard installation includes
- Outdoor unit on a wall bracket or stand, like an AC
- Insulated copper pipe between outdoor unit and tank, up to 2.5 m
- Tank connected to your existing plumbing within 2 m
- Safety valve and drain piped, commissioning and a demonstration
Quoted separately
Extra copper pipe per metre, a stand or plinth, a new MCB or cable run, and removing an old geyser are quoted separately.
Looking after it
- Every 6 months: Check the magnesium anode and replace it when used up; clean the tank
- Every year: Operate the safety valve lever and clean the outdoor coil of dust
- Before a long break: Switch off, drain the tank in freezing areas, and close the valves
Warranty
- 5 years on the enamel-lined tank
- 5 years on the compressor
- 3 years on the whole unit, parts and labour
Register online within 30 days. Installed by Sunniva or an authorised partner, used within the water-quality limits, and the magnesium anode checked every 6 months.
Buying for a business?
Send your GSTIN with your order and we issue a GST invoice in your company name, so you can claim the ₹16,002 GST as input tax credit. Depreciation on the basic price may also apply; your CA confirms eligibility and the rate.
Every Sunniva Home heat pump has one price, the same in every city, for one unit or fifty. See our terms of sale, cancellation and refunds and shipping and installation.
Considering the all-in-one instead?
Prefer a single unit with nothing to fit on a wall?
Common questions
Does it work in winter?
Yes, down to −7 °C outside air, with a 2 kW backup heater for the coldest days.
How much will I save?
About 4 units of heat for every unit of electricity, so up to 75% less power than an electric geyser for the same hot water. Actual savings depend on use, tariff and climate.
Who installs it in my city?
Our own team in our strongest cities, authorised partners elsewhere. Installation is ₹3,000 in metro cities, ₹5,000 in tier 2 cities and ₹6,000 everywhere else; check your pin code in the Installation section.
Where does the outdoor unit go?
On a balcony, terrace or outside wall, like an AC outdoor unit, within 2.5 m of pipe run from the tank. Keep the coil and fan clear of walls and screens.
Can I keep my existing geyser plumbing?
Yes. The tank connects to your existing hot and cold lines; the installer adds a safety valve, non-return valve and drain as shown in the schematic.
Products › Sunniva Home Split › 200 L
Sunniva Home Split 200
A 200 L enamel-lined tank indoors and a quiet outdoor unit outside, joined by an insulated copper pipe up to 2.5 m long. Best for a family of 3–4. Hot water up to 60 °C on the heat pump alone, for up to 75% less electricity than an electric geyser.
MRP
Includes 18% GST and delivery to any pin code. ₹88,898 basic + ₹16,002 GST; business buyers claim the GST back.
Pre-order online or on WhatsApp now. Deliveries start in early 2027, and you can cancel free any time before dispatch.

Choose the size
Allow about 40–60 litres of hot water per person per day. Not sure? Tell us your family size and bathrooms on WhatsApp.
Specifications
| Tank capacity | 200 L |
|---|---|
| Heating capacity | 3.5 kW |
| Rated power input | 870 W |
| COP* | 4.0 |
| Running current | 4.0 A |
| Hot water | 55 °C rated, up to 60 °C on the heat pump, 75 °C with backup heater |
| Outdoor air range | −7 °C to 43 °C |
| Refrigerant / compressor | R410A · GMCC rotary |
| Noise (outdoor unit) | ≤ 42 dB(A) |
| Outdoor unit (W×D×H), weight | 766×268×550 mm, 28 kg |
| Tank (Ø×H), weight | 510×1,710 mm, 68 kg |
| Water connections | DN15 |
| Heat exchanger | Micro-channel coil wrapped outside the enamel-lined steel tank |
| Backup heater | 2 kW with thermostat |
| Power supply | 220–240 V / 50 Hz / 1 ph, Class I, IPX4 |
| Basic price | ₹88,898 |
| GST (18%), claimable for business use | ₹16,002 |
| Price incl. GST and delivery | ₹1,04,900 |
*Rated at outdoor air 20 °C (wet bulb 15 °C), water heated from 15 °C to 55 °C. Specifications may change without notice.
Functions, features and benefits
Set the water anywhere from 20 to 60 °C on a backlit touch panel. The keys lock themselves when the unit is idle.
Children and guests can’t change your settings by accidentA built-in clock and two programmable heating windows a day.
Heat in off-peak tariff hours, or just before the morning rushThe 2 kW heater starts automatically below an outdoor temperature your installer sets.
Hot water stays reliable through the coldest spellsWhen frost builds on the outdoor coil in winter, the unit clears it briefly and goes back to heating.
Full output on cold mornings with nothing for you to doBelow 5 °C outside, the unit runs itself to keep the water moving and heats the tank to 12 °C if it nears freezing.
No frozen tank or burst pipes in hill stationsAbove 26 °C outside the fan drops to low speed.
Quieter running on summer nights, when you need the least heatLive readings of water, coil, gas and air temperatures, and a clear code if anything goes wrong.
Our technician knows the fault before reaching you, so most fixes take one visitHigh- and low-pressure switches, discharge-temperature and compressor over-current protection.
The system shuts down safely before anything can be damagedBlue-crystal enamel lining resists corrosion and scale; thick foam keeps water hot for hours.
Longer tank life and hot water left over from yesterday’s heatingHow it works
- Air in. The outdoor fan pulls air through the finned coil; even at −7 °C it holds useful heat.
- Evaporator. Cold refrigerant soaks up that heat and boils into a vapour.
- Compressor. The GMCC rotary compressor turns the vapour into a hot, high-pressure gas.
- Hot gas travels indoors. Through insulated copper pipe, up to 2.5 m. No water pipes run through the wall.
- Micro-channel exchanger. The gas circulates through flat aluminium micro-channels bonded to the outside of the tank, heats the water through the steel wall and condenses to a liquid.
- Expansion valve. Back outdoors the liquid's pressure drops, it turns cold and the cycle repeats.
Installation
A fixed charge by city, the same for every model. Installed by Sunniva or an authorised partner.
One fixed charge per unit for standard installation, the same for every model. City tiers follow the Government of India city classification. Extras listed below are quoted separately.
Standard installation includes
- Outdoor unit on a wall bracket or stand, like an AC
- Insulated copper pipe between outdoor unit and tank, up to 2.5 m
- Tank connected to your existing plumbing within 2 m
- Safety valve and drain piped, commissioning and a demonstration
Quoted separately
Extra copper pipe per metre, a stand or plinth, a new MCB or cable run, and removing an old geyser are quoted separately.
Looking after it
- Every 6 months: Check the magnesium anode and replace it when used up; clean the tank
- Every year: Operate the safety valve lever and clean the outdoor coil of dust
- Before a long break: Switch off, drain the tank in freezing areas, and close the valves
Warranty
- 5 years on the enamel-lined tank
- 5 years on the compressor
- 3 years on the whole unit, parts and labour
Register online within 30 days. Installed by Sunniva or an authorised partner, used within the water-quality limits, and the magnesium anode checked every 6 months.
Buying for a business?
Send your GSTIN with your order and we issue a GST invoice in your company name, so you can claim the ₹16,002 GST as input tax credit. Depreciation on the basic price may also apply; your CA confirms eligibility and the rate.
Every Sunniva Home heat pump has one price, the same in every city, for one unit or fifty. See our terms of sale, cancellation and refunds and shipping and installation.
Considering the all-in-one instead?
Prefer a single unit with nothing to fit on a wall?
Common questions
Does it work in winter?
Yes, down to −7 °C outside air, with a 2 kW backup heater for the coldest days.
How much will I save?
About 4 units of heat for every unit of electricity, so up to 75% less power than an electric geyser for the same hot water. Actual savings depend on use, tariff and climate.
Who installs it in my city?
Our own team in our strongest cities, authorised partners elsewhere. Installation is ₹3,000 in metro cities, ₹5,000 in tier 2 cities and ₹6,000 everywhere else; check your pin code in the Installation section.
Where does the outdoor unit go?
On a balcony, terrace or outside wall, like an AC outdoor unit, within 2.5 m of pipe run from the tank. Keep the coil and fan clear of walls and screens.
Can I keep my existing geyser plumbing?
Yes. The tank connects to your existing hot and cold lines; the installer adds a safety valve, non-return valve and drain as shown in the schematic.