How big a heat pump does your pool need?
Move the sliders. You get the capacity in kilowatts, the Sunniva model that covers it, and what it costs to run against an electric immersion heater or a diesel boiler. Every figure updates as you type, and nothing is hidden — the assumptions are listed at the bottom.
Your pool
Rough numbers are fine — surface area matters far more than depth.
Temperatures & heat-up
26 – 28 °C suits most swimmers; 30 °C and above for therapy or small children.
Where the pool is
Wind and an open sky drive the losses. A cover changes everything.
What you pay for energy
Change these to your own tariff — the comparison is only as good as the numbers you put in.
Engineering assumptions change only if you know why
- Pool volume
- —
- Water surface area
- —
- Temperature rise needed
- —
- Heat-up load
- —
- Holding load, uncovered
- —
- Average load once warm
- —
- Heat needed per day
- —
Where the heat goes
Cost to run for one day
What it pays back, and what it stops
Want this sizing checked by an engineer?
Your name, phone and email go on the saved sheet and let our team confirm the selection against your actual site — cover, wind exposure, filtration and pipe runs all shift the answer. All three are needed before the sheet can be sent or saved.
How this is worked out
- Heat-up load = volume × 1.163 × temperature rise ÷ hours. That constant is water's heat capacity, 4.186 kJ/kg·K, in kWh per m³ per °C.
- Evaporation is the big one on an outdoor pool — usually well over half the loss. Calculated from the surface evaporation coefficient 25 + 19v kg/m²h, where v is the air speed over the water, times the humidity difference between saturated air at pool temperature and the actual air.
- Convection uses (3.1 + 4.1v) W/m²·K on the water-to-air difference; radiation uses a water emissivity of 0.95 against a sky 8 °C below air temperature outdoors, and air temperature indoors. A ground and pipework allowance is added on top.
- Payback is simple payback — the price you type in, divided by the annual saving. No finance, no maintenance, no discounting, and no price of ours is assumed or disclosed. Carbon is the displaced fuel’s emissions minus the electricity the heat pump draws, at the Indian grid average of 0.71 kg CO₂ per unit. Every factor is a slider, and the saved sheet records what was used.
- A cover is taken to cut evaporation to 5 % and convection and radiation to 35 %, for the hours it is on.
- The design air temperature is applied for all 24 hours. Real nights are colder than that, which would make the loss worse — but most pools are covered overnight or allowed to drift a few degrees, which is why the cover setting moves the daily figure so much. Set the ambient to your average day-and-night temperature if you want the running cost rather than the sizing case.
- Sizing uses the uncovered holding load plus the heat-up load, because the machine has to do both at once on the coldest day. Running cost uses the day-weighted average, because that is what the pool actually consumes.
- Capacity and COP are read off the chosen model's own published table and interpolated against your design ambient — not a fixed COP. Below 10 °C ambient the figures are extrapolated past the certified range and the panel says so.
- Indicative only. Static head, filtration, pipe runs, water chemistry and local code all affect the final selection — confirm with Sunniva Encon LLP before ordering.
Calculated for
What you entered
Result
Running cost & savings
How this was worked out
Talk to Sunniva
Contact
+91 93213 65103sales@sunnivaencon.com
www.sunnivaencon.com
Office
C‑443, Oshiwara Industrial Centre Premises CHS, New Link Road, Goregaon West, MumbaiHow big a heat pump does your pool need?
Move the sliders. You get the capacity in kilowatts, the Sunniva model that covers it, and what it costs to run against an electric immersion heater or a diesel boiler. Every figure updates as you type, and nothing is hidden — the assumptions are listed at the bottom.
Your pool
Rough numbers are fine — surface area matters far more than depth.
Temperatures & heat-up
26 – 28 °C suits most swimmers; 30 °C and above for therapy or small children.
Where the pool is
Wind and an open sky drive the losses. A cover changes everything.
What you pay for energy
Change these to your own tariff — the comparison is only as good as the numbers you put in.
Engineering assumptions change only if you know why
- Pool volume
- —
- Water surface area
- —
- Temperature rise needed
- —
- Heat-up load
- —
- Holding load, uncovered
- —
- Average load once warm
- —
- Heat needed per day
- —
Where the heat goes
Cost to run for one day
What it pays back, and what it stops
Want this sizing checked by an engineer?
Your name, phone and email go on the saved sheet and let our team confirm the selection against your actual site — cover, wind exposure, filtration and pipe runs all shift the answer. All three are needed before the sheet can be sent or saved.
How this is worked out
- Heat-up load = volume × 1.163 × temperature rise ÷ hours. That constant is water's heat capacity, 4.186 kJ/kg·K, in kWh per m³ per °C.
- Evaporation is the big one on an outdoor pool — usually well over half the loss. Calculated from the surface evaporation coefficient 25 + 19v kg/m²h, where v is the air speed over the water, times the humidity difference between saturated air at pool temperature and the actual air.
- Convection uses (3.1 + 4.1v) W/m²·K on the water-to-air difference; radiation uses a water emissivity of 0.95 against a sky 8 °C below air temperature outdoors, and air temperature indoors. A ground and pipework allowance is added on top.
- Payback is simple payback — the price you type in, divided by the annual saving. No finance, no maintenance, no discounting, and no price of ours is assumed or disclosed. Carbon is the displaced fuel’s emissions minus the electricity the heat pump draws, at the Indian grid average of 0.71 kg CO₂ per unit. Every factor is a slider, and the saved sheet records what was used.
- A cover is taken to cut evaporation to 5 % and convection and radiation to 35 %, for the hours it is on.
- The design air temperature is applied for all 24 hours. Real nights are colder than that, which would make the loss worse — but most pools are covered overnight or allowed to drift a few degrees, which is why the cover setting moves the daily figure so much. Set the ambient to your average day-and-night temperature if you want the running cost rather than the sizing case.
- Sizing uses the uncovered holding load plus the heat-up load, because the machine has to do both at once on the coldest day. Running cost uses the day-weighted average, because that is what the pool actually consumes.
- Capacity and COP are read off the chosen model's own published table and interpolated against your design ambient — not a fixed COP. Below 10 °C ambient the figures are extrapolated past the certified range and the panel says so.
- Indicative only. Static head, filtration, pipe runs, water chemistry and local code all affect the final selection — confirm with Sunniva Encon LLP before ordering.
Calculated for
What you entered
Result
Running cost & savings
How this was worked out