Domestic hot water
Residential · 150 – 500 L

A split unit — outside stays outside

The compressor sits outdoors and the cylinder sits indoors, with nothing but a pair of thin refrigerant lines between them. No hot water runs through the wall, no tank has to stand in the weather, and the cylinder can go where the bathrooms are rather than where the roof allows.

Sunniva Domestic Split Unit
Storage
150–500L
five tank sizes
Heating capacity
3.3–7.2kW
rated, per model
Hot water to
55°C
on the heat pump alone
Ambient range
−5 to 43°C
single phase, 220 V

Is this the right range for you?

Two minutes here saves a wasted quotation. The boundaries below are the published ones, not sales judgement.

Yes, if all of these are true

  • A flat, villa or house on a single hot water system
  • 150 to 500 litres of storage is enough
  • The cylinder has to sit indoors, away from the outdoor unit
  • You are retrofitting where a geyser used to be

Look at another range if

Applications

Where this range is normally installed.

Apartments
Villas
Retrofit homes

Key features

What is inside the cabinet, and why each of them is there.

Micro-channel heat exchanger wrapped around the outside of the tank

Glass enamel lined steel cylinder with a magnesium anode

R134a rotary compressor, 220 V single phase

Electric back-up element for 75 °C when it is wanted

Intelligent wired controller with a 5 m lead

Six protections including high and low refrigerant pressure

Models in this range

Five tank sizes on three outdoor units. Figures are the manufacturer’s ratings — read the note under the table before sizing to a cold-weather duty.

ModelStorageHeating capacityRated inputCOPElectric back-upTank ø × H
SE-AH-4|150S150 L3.3 kW800 W4.101.5 kW500 × 1330 mm
SE-AH-5|200S200 L5 kW1200 W4.171.5 kW500 × 1680 mm
SE-AH-5|300S300 L5 kW1200 W4.172 kW560 × 1805 mm
SE-AH-7|400S400 L7.2 kW1750 W4.112 kW700 × 1590 mm
SE-AH-7|500S500 L7.2 kW1750 W4.112 kW700 × 1940 mm

Heating capacity, input power and COP are the manufacturer's rated figures. The source sheet does not state the ambient and water temperatures they were measured at, so they are published here as rated values rather than against a named test condition. Ask us before sizing to a cold-weather duty. A 100 litre model (SE-AH-4|100S) also sells on the channel price list; its data sheet is being prepared and it is not listed above.

Benefits

What this range does for the building, rather than what is in the box.

The cylinder goes where you want it

Refrigerant runs between the outdoor unit and the tank, not water. Three metres of pipe comes as standard, so the tank can sit in a utility room next to the bathrooms instead of on the roof.

Nothing hot in the wall

The heat is made at the tank, not carried to it. There is no insulated flow and return to lose heat in a wall cavity, and nothing outdoors to freeze.

Water never meets refrigerant

The micro-channel exchanger is bonded to the outside of the cylinder, under the insulation. A refrigerant leak cannot reach the potable water.

55 °C on the heat pump, 75 °C when you need it

The compressor does the everyday work. The element is there for a cold morning or a full house, not for every draw-off.

How much storage do you need?

The domestic sizing tool is in preparation. In the meantime the calculator index will point you at the nearest one, or send us the occupancy and we will size it.

And what every Sunniva heat pump gives you

True of the whole range, not just this one.

  • Up to 75 % off water heating against electric, LPG or PNG
  • Quick payback and strong return on investment
  • The longest product life of any common water-heating technology
  • Silent operation
  • Hot water round the year, independent of sunlight
  • Lower carbon emissions
  • Negligible maintenance cost
  • Saves space against a boiler or a solar-thermal field

Common questions

The ones our engineers are actually asked.

How far can the outdoor unit be from the tank?
Three metres of copper comes as standard, which covers the usual case of a balcony or terrace unit and a cylinder just inside. Longer runs are possible — tell us the distance and the height difference and we will confirm the charge.
Does the refrigerant touch the drinking water?
No. The micro-channel exchanger is bonded to the outside of the steel cylinder, underneath the insulation, so the two circuits never share a wall that could leak into the water.
What happens in winter?
The heat pump works down to −5 °C ambient. Below that, or when the whole house wants hot water at once, the built-in electric element covers the gap and can take the tank to 75 °C. For genuinely cold sites, look at the EVI range instead.
How is this different from the All in One?
Same idea, split into two boxes. The All in One puts the heat pump and the tank in one cabinet, which is simpler to install but has to stand outdoors or in a service area. The split lets the cylinder live indoors.
How much noise does the outdoor unit make?
52 dB(A) on the smaller units and 55 dB(A) on the 2 hp ones, measured at the manufacturer’s standard distance — about the level of a domestic split air conditioner.