The complete range of Sunniva heat pumps
From a warm pool to 120 °C process heat
Fifteen categories on one ladder. Every Sunniva machine does the same thing — moves heat instead of burning something to make it — and what separates them is how hot they will take the water, and how much of it. Start with the temperature you need.
The range, by temperature
Published maximum water outletEach bar is the hottest water that category is published to deliver. Darker means hotter. Select a bar to open that range.
Bars show maximum water outlet temperature only; capacity is printed beside them, not plotted. All in One, Monoblock, Domestic Split Unit, Geothermal, Customized, the dryer and the storage tanks are not on the chart — they publish no maximum water outlet figure, and the dryer moves heat into air rather than into water. Every figure also appears in the list below.
All fifteen categories
Grouped by dutySanitary hot water first, then pool duty, then the ranges that go hotter — followed by the ground-coupled range, the dryer and the storage tanks that pair with any of them.
Hot water to 60 °C
Sanitary hot water, from a farmhouse to a campus 5 categoriesAll in One Heat Pump
Heat pump and enamelled tank in a single cabinet — one unit, one connection, nothing to plumb between.
Monoblock Heat Pump
Compact monoblock with the circulation pump built in. Heating through winter, cooling in summer as an option.
Domestic Split Unit
Outdoor unit outside, cylinder indoors, refrigerant between them — so nothing hot runs through the wall and the cylinder can sit where the bathroom is.
Commercial Heat Pump
The workhorse range for bulk sanitary hot water, from a small hotel block to a full campus.
EVI Heat Pump
Enhanced vapour injection holds 60 °C output with the ambient at −25 °C, and needs no auxiliary heater to do it.
Pool duty
Water held at swimming temperature, year round 1 categorySwimming Pool Heat Pump
Titanium-in-PVC-shell exchanger built for chlorinated water. Heating in winter, cooling in summer as an option.
Hot water & process to 80 °C
Where a boiler used to be the only answer 2 categoriesHigh Temperature Heat Pump
80 °C sanitary and process water without a boiler, across an ambient range of 7 – 43 °C.
Water Source Heat Pump
Hot and chilled water from the same machine at the same time — no fans, no dependence on the ambient.
Industrial process heat
95 – 120 °C, without a boiler 2 categoriesSuper High Temperature Heat Pump
Process heat to 95 °C on low-GWP R515B, taken from ambient air alone — no waste heat needed.
Ultra High Temperature Heat Pump
120 °C process water on R245fa, in two cycles — one fed by waste heat, one by ambient air.
Ground coupled
A source that barely moves through the year 1 categoryGeothermal Heat Pump
Ground-coupled exchange against a temperature that stays near-constant, summer or winter.
Drying
Heat pumps that take the water out instead of putting it in 1 categoryHeat Pump Dryer
The same closed cycle, pointed the other way: it dries the air, warms it and sends it back round, so the heat is recovered instead of vented up a flue.
Storage
Tanks to pair with any source 2 categoriesGlass Lined Tanks
Vitreous enamel fused to steel at 900 °C, CFC-free PU insulation, Incoloy 800 element and a magnesium anode.
Ceramic Lined Tanks
Ceramic-coated against corrosion, 50 mm rockwool under aluminium cladding. Pressurised or non-pressurised.
Engineered to order
When the catalogue does not have it 1 categoryCustomized Heat Pump
A duty above the standard range, a water that would eat an ordinary exchanger, an ambient nobody designs for, or a refrigerant your reporting position requires.
How the model numbers work
Read any code without ringing usEvery Sunniva model number is built the same way, so a code on a drawing or a purchase order tells you what the machine is before you look anything up.
An SE-EVI-46U is a Sunniva enhanced-vapour-injection machine of 46 kW in the U cabinet. Nothing in the code is decorative.
| Code | Family | Example | What it means |
|---|---|---|---|
| AH | Air to water | SE-AH-25U | The main line: an air-source machine making hot water. Also carries the monoblock and all-in-one variants, marked by their own suffixes below. |
| SP | Swimming pool | SE-SP-50U | Titanium condenser throughout, because chlorinated water destroys anything else. |
| EVI | Enhanced vapour injection | SE-EVI-46U | A second injection port into the compressor, which is what keeps capacity up when the air goes cold. |
| HT | High temperature | SE-HT-29U | Process water to 80 °C. |
| SHT | Super high temperature | SE-SHT-50V | To 95 °C on R515B, from ambient air. |
| UHT | Ultra high temperature | SE-UHT-45V | To 120 °C. The cascade build, which takes its heat from ambient air. |
| WWUHT | Water to water, ultra high temperature | SE-WWUHT-50 | The single-cycle 120 °C machine. Water on both sides, so it needs a warm source — which is exactly what the WW says. |
| GL | Glass lined tank | SE-GL-300 | Storage, not a heat pump. The number is litres. |
The rest of the code
| Part | Example | What it means | |
|---|---|---|---|
| The number | SE-AH-25U | Heating capacity in kilowatts, at that range's own rated test point. Ranges are rated at different conditions, so a 25 in one family and a 25 in another are not measured the same way — each model's data sheet states its own. | |
| M | SE-AH-7M | Monoblock: the water circulation pump is built in, so installation is pipe it and plug it in. | |
| U and V | SE-AH-25U · SE-AH-140V | The cabinet the machine is built in. V is the V-coil frame used on the larger duties; U is the smaller box. | |
| S, with a tank volume | SE-AH-5|300S | A split unit — the compressor outdoors, the cylinder indoors. The number after the bar is the cylinder in litres. | |
| A second number | SE-AH-6-420 | On an all-in-one, the volume of the built-in tank in litres. The machine and its cylinder are one cabinet. | |
| C | SE-SHT-50VC | Cascade: two refrigerants in series, so the machine reaches its delivery temperature from ambient air rather than needing a warm source. | |
Capacities are stated at each range’s own rated test condition, and those conditions differ between ranges — a swimming pool machine and an ultra high temperature machine are not measured against the same air or the same water. Every model’s data sheet states the condition its figures were taken at.
Before you choose
The questions that come before a range doesEach range page answers the questions about that machine. These are the ones that need more than one range to answer.
Which range do I need?
What is the difference between the All-in-One, the Monoblock and the Split?
Can you build something that is not on this list?
What can I change on a standard machine?
Where do the figures on this site come from?
What do you need from me to size it and quote?
Not sure which rung you are on?
Tell us the draw-off pattern, the water temperature you need and the ambient it has to work in. We will size it — and say so if a smaller machine will do.
The complete range of Sunniva heat pumps
From a warm pool to 120 °C process heat
Fifteen categories on one ladder. Every Sunniva machine does the same thing — moves heat instead of burning something to make it — and what separates them is how hot they will take the water, and how much of it. Start with the temperature you need.
The range, by temperature
Published maximum water outletEach bar is the hottest water that category is published to deliver. Darker means hotter. Select a bar to open that range.
Bars show maximum water outlet temperature only; capacity is printed beside them, not plotted. All in One, Monoblock, Domestic Split Unit, Geothermal, Customized, the dryer and the storage tanks are not on the chart — they publish no maximum water outlet figure, and the dryer moves heat into air rather than into water. Every figure also appears in the list below.
All fifteen categories
Grouped by dutySanitary hot water first, then pool duty, then the ranges that go hotter — followed by the ground-coupled range, the dryer and the storage tanks that pair with any of them.
Hot water to 60 °C
Sanitary hot water, from a farmhouse to a campus 5 categoriesAll in One Heat Pump
Heat pump and enamelled tank in a single cabinet — one unit, one connection, nothing to plumb between.
Monoblock Heat Pump
Compact monoblock with the circulation pump built in. Heating through winter, cooling in summer as an option.
Domestic Split Unit
Outdoor unit outside, cylinder indoors, refrigerant between them — so nothing hot runs through the wall and the cylinder can sit where the bathroom is.
Commercial Heat Pump
The workhorse range for bulk sanitary hot water, from a small hotel block to a full campus.
EVI Heat Pump
Enhanced vapour injection holds 60 °C output with the ambient at −25 °C, and needs no auxiliary heater to do it.
Pool duty
Water held at swimming temperature, year round 1 categorySwimming Pool Heat Pump
Titanium-in-PVC-shell exchanger built for chlorinated water. Heating in winter, cooling in summer as an option.
Hot water & process to 80 °C
Where a boiler used to be the only answer 2 categoriesHigh Temperature Heat Pump
80 °C sanitary and process water without a boiler, across an ambient range of 7 – 43 °C.
Water Source Heat Pump
Hot and chilled water from the same machine at the same time — no fans, no dependence on the ambient.
Industrial process heat
95 – 120 °C, without a boiler 2 categoriesSuper High Temperature Heat Pump
Process heat to 95 °C on low-GWP R515B, taken from ambient air alone — no waste heat needed.
Ultra High Temperature Heat Pump
120 °C process water on R245fa, in two cycles — one fed by waste heat, one by ambient air.
Ground coupled
A source that barely moves through the year 1 categoryGeothermal Heat Pump
Ground-coupled exchange against a temperature that stays near-constant, summer or winter.
Drying
Heat pumps that take the water out instead of putting it in 1 categoryHeat Pump Dryer
The same closed cycle, pointed the other way: it dries the air, warms it and sends it back round, so the heat is recovered instead of vented up a flue.
Storage
Tanks to pair with any source 2 categoriesGlass Lined Tanks
Vitreous enamel fused to steel at 900 °C, CFC-free PU insulation, Incoloy 800 element and a magnesium anode.
Ceramic Lined Tanks
Ceramic-coated against corrosion, 50 mm rockwool under aluminium cladding. Pressurised or non-pressurised.
Engineered to order
When the catalogue does not have it 1 categoryCustomized Heat Pump
A duty above the standard range, a water that would eat an ordinary exchanger, an ambient nobody designs for, or a refrigerant your reporting position requires.
How the model numbers work
Read any code without ringing usEvery Sunniva model number is built the same way, so a code on a drawing or a purchase order tells you what the machine is before you look anything up.
An SE-EVI-46U is a Sunniva enhanced-vapour-injection machine of 46 kW in the U cabinet. Nothing in the code is decorative.
| Code | Family | Example | What it means |
|---|---|---|---|
| AH | Air to water | SE-AH-25U | The main line: an air-source machine making hot water. Also carries the monoblock and all-in-one variants, marked by their own suffixes below. |
| SP | Swimming pool | SE-SP-50U | Titanium condenser throughout, because chlorinated water destroys anything else. |
| EVI | Enhanced vapour injection | SE-EVI-46U | A second injection port into the compressor, which is what keeps capacity up when the air goes cold. |
| HT | High temperature | SE-HT-29U | Process water to 80 °C. |
| SHT | Super high temperature | SE-SHT-50V | To 95 °C on R515B, from ambient air. |
| UHT | Ultra high temperature | SE-UHT-45V | To 120 °C. The cascade build, which takes its heat from ambient air. |
| WWUHT | Water to water, ultra high temperature | SE-WWUHT-50 | The single-cycle 120 °C machine. Water on both sides, so it needs a warm source — which is exactly what the WW says. |
| GL | Glass lined tank | SE-GL-300 | Storage, not a heat pump. The number is litres. |
The rest of the code
| Part | Example | What it means | |
|---|---|---|---|
| The number | SE-AH-25U | Heating capacity in kilowatts, at that range's own rated test point. Ranges are rated at different conditions, so a 25 in one family and a 25 in another are not measured the same way — each model's data sheet states its own. | |
| M | SE-AH-7M | Monoblock: the water circulation pump is built in, so installation is pipe it and plug it in. | |
| U and V | SE-AH-25U · SE-AH-140V | The cabinet the machine is built in. V is the V-coil frame used on the larger duties; U is the smaller box. | |
| S, with a tank volume | SE-AH-5|300S | A split unit — the compressor outdoors, the cylinder indoors. The number after the bar is the cylinder in litres. | |
| A second number | SE-AH-6-420 | On an all-in-one, the volume of the built-in tank in litres. The machine and its cylinder are one cabinet. | |
| C | SE-SHT-50VC | Cascade: two refrigerants in series, so the machine reaches its delivery temperature from ambient air rather than needing a warm source. | |
Capacities are stated at each range’s own rated test condition, and those conditions differ between ranges — a swimming pool machine and an ultra high temperature machine are not measured against the same air or the same water. Every model’s data sheet states the condition its figures were taken at.
Before you choose
The questions that come before a range doesEach range page answers the questions about that machine. These are the ones that need more than one range to answer.
Which range do I need?
What is the difference between the All-in-One, the Monoblock and the Split?
Can you build something that is not on this list?
What can I change on a standard machine?
Where do the figures on this site come from?
What do you need from me to size it and quote?
Not sure which rung you are on?
Tell us the draw-off pattern, the water temperature you need and the ambient it has to work in. We will size it — and say so if a smaller machine will do.