Heat pump and 200 L enamelled tank in one cabinet. The condenser is wrapped round the outside of the tank, so refrigerant never enters the water. Hot water to 75 °C, R134a, single-phase.

Sunniva SE-AH-2-200 all in one heat pump water heater
Heating capacity
1.6kW
Rated, heat pump
COP
3.85
Rated
Storage
200L
Enamelled steel tank
Hot water output
36L/h
Rated, heat pump alone

Performance

Rated figures, and what they mean in litres
Rated dutyheat pump mode
Heating capacity
1,600W
Rated input power
415W
COP
3.85
Hot waterrated
Hot water output
36L/h
Full tank at that rate
≈ 5.6h
Maximum water temperature
75°C
Maximumfor the electrician
Max input power
3,200W
Max input current
16A
Electric heater
2.5kW

Technical specifications

SE-AH-2-200
Technical specifications for SE-AH-2-200
ParameterUnitSpecification
Heat pump
Heating capacityW1,600
Rated input powerW415
COP—3.85
Rated hot water outputL/h36
Maximum water temperature°C75
Ambient operating range°C0 to 45
Refrigerant—R134a
Compressor—Panasonic
Condenser—Micro-channel heat exchanger
Noise leveldB(A)≤ 48
Tank & cabinet
Rated volumeL200
Inner tank—Enamelled steel, 2.5 mm
Insulation (polyurethane foam)mm45
Outer casing—Painted galvanised steel
Colour—White
Water pressureMPa0.8
Product sizemmø 525 × 1955
Net weightkg114
Electrical & control
Power supply—220–240 V / 50 Hz / 1-ph
Maximum input powerW3,200
Maximum input currentA16
Electric heaterW2,500
Required MCB—32 A × 2-pole
Required cable—3-core × 2.5 mm² copper
Control—Remote display

Rated figures

  • Heating capacity, input power, COP and hot water output are the rated figures on the Sunniva data sheet. The sheet does not name the ambient and water temperatures they were measured at, so they are published as rated values. Ask us before sizing to a cold-weather duty.
  • Derived: full-tank time is the tank volume divided by the rated hot water output.

Installation requirement

  • Dedicated single-phase supply: 32 A × 2-pole MCB and 3-core × 2.5 mm² copper cable, as the data sheet specifies.
  • Fit the pressure relief valve supplied and pipe its discharge to a drain.
  • The unit takes its heat from the air round it — give the top section free air in and out.

Site installation schematic

One cabinet: heat pump on top, tank below, nothing to plumb between them
Level floor, indoors or under cover COMP Outdoor-temperature air in Cooled air out Hot water to taps Relief valve, piped to drain Cold water in Stop valve · non-return Tank drain MCB Dedicated 1-ph supply 123456
Hot waterCold water / cooled airWrapped condenserPower
  1. 1Air in. The fan draws outdoor-temperature air across the evaporator, where the refrigerant boils and takes heat from it.
  2. 2Compressor. The compressor raises the refrigerant vapour to a high temperature.
  3. 3Heat into the water. The micro-channel condenser is wrapped round the outside of the tank under the insulation. It gives its heat to the water through the tank wall, so refrigerant never touches the water.
  4. 4Cooled air out. The air leaves cooler than it came in. Do not duct it back to the intake.
  5. 5Water in and out. Cold water enters low in the tank and hot water is drawn from the top, so the hottest water is always at the outlet.
  6. 6Electric back-up. The 2.5 kW element in the tank covers a cold morning or a full house, and can take the tank to 75 °C.

Schematic — not to scale; connection positions vary by model.

Choosing a size

Size on the people and the draw-off
This model
Hot water per person per day40–60 L
Suitsabout 3–5 people
Full tank at the rated output≈ 5.6 h on the heat pump
Keeps up with≈ 36 L/h of draw-off

Why all in one

  • One unit, one water connection, one power connection — no separate cylinder, pump or interconnecting pipe to design.
  • The condenser sits outside the tank wall, so a refrigerant leak cannot reach the water.
  • The 2.5 kW heater covers a cold morning or a full house, and takes the tank to 75 °C when wanted.

The range at a glance

SE-AH-2-200 is marked
ModelTank LHeating kWCOPL/hFull tank h*Ambient °CSize mmWeight kg
SE-AH-2-1501501.63.85344.40 to 45ø 525 × 1955102
SE-AH-2-2002001.63.85365.60 to 45ø 525 × 1955114
SE-AH-3-3003003.34.08754.0−5 to 43ø 650 × 1950129
SE-AH-6-3503505.34.081183.0−5 to 43650 × 937 × 1720192
SE-AH-6-4204205.34.081183.6−5 to 43735 × 1006 × 1720207

* Derived: tank volume divided by the rated hot water output. SE-AH-6-350 and SE-AH-6-420 are the same heat pump on two tank sizes, which is why their capacity and output match.

Installation steps

Follow in order — fill the tank before switching on
  1. Stand the unit on a level floor that takes 314 kg filled, with clear air round the top section.
  2. Connect the cold inlet through a stop valve and non-return valve; fit the relief valve supplied on the hot side and pipe its discharge to a drain.
  3. Connect the hot outlet to the taps, and run the condensate and tank drain to a drain point.
  4. Fill the tank completely and open a hot tap until water runs without air — never power the unit with the tank empty: the heater will burn out.
  5. Have a licensed electrician run a dedicated supply on a 32 A × 2-pole MCB with 3-core × 2.5 mm² copper cable, earthed.
  6. Switch on, set the water temperature on the remote display, and check for leaks once the tank is hot.

Site checklist

What has to be true before the unit arrives
Site
FloorLevel, and takes ≈ 314 kg filled (114 kg unit + 200 L water)
Spaceø 525 × 1955 mm, plus room round the air inlet and outlet and to service the anode and heater
AirFree air to the intake and away from the outlet. A room smaller than a garage or utility area will cool down
SupplyDedicated 220–240 V single-phase: 32 A × 2-pole MCB, 3-core × 2.5 mm² copper cable
WaterMains or tank feed at no more than 0.8 MPa; fit a pressure-reducing valve above that
DrainFor the relief valve discharge, the condensate and the tank drain

What comes with it

  • Panasonic compressor, R134a
  • Micro-channel condenser wrapped round the tank
  • Enamelled steel, 2.5 mm inner tank, 45 mm PU insulation
  • 2.5 kW electric back-up heater
  • Remote display

Documents & links

Scan with a phone camera, or tap the buttons

Talk to Sunniva

Scan to open a WhatsApp chat

Documentation

Scan to open the latest revision on sunnivaencon.com

Connect & review

Product videos and customer feedback

SE-AH-2-200 · Technical Data Sheet. Specifications are subject to change without prior notice.  ← All All-in-One models