Sunniva Encon LLP · Application NoteAN-011 · Rev 0 · 23 Oct 2026
Dairy and food processing

Retort water preheated from retort cooling water

How a cannery running 12 retort cycles a day can preheat its retort water to 110 °C with a heat pump that recovers retort cooling-water heat, cutting furnace-oil use.

Application#11 Canning (retort water preheating and sterilisation)
Temperature band60–120 °C
Sunniva selection4 × SE-WWUHT-27
Replacesfurnace-oil fired steam boiler

▶Video: Waste-heat recovery heat pumps

V10 · 2–2.5 min
Waste-heat recovery heat pumps

Lifting warm water from condensers, effluent and process cooling to useful heat

Video coming soon

01Problem statement

  • Slow come-up. Bringing product and process water up to temperature takes much of the cycle time and most of the steam.
  • Cooling heat is thrown away. After sterilisation, product is cooled with water that leaves at 50–70 °C and goes to drain or a cooling tower.
  • Steam peaks. Several retorts starting together cause steam peaks that the boiler struggles to meet.
  • Losses between fuel and process. Burning furnace oil in a boiler or heater and distributing the heat loses a quarter or more of the fuel's energy before it reaches the process.
  • Compliance, safety and handling. Fired equipment brings boiler inspections, fuel storage and unloading, flue emissions and an attendant on every shift.

02Use case

The reference plant packs ready-to-eat curries, sweet corn and fruit in syrup in cans and retort pouches. Four water-immersion retorts run about 12 cycles a day, with about 1 tonne of product per cycle. Each retort has a storage drum for process water that is reused cycle to cycle.

Heat userProcess temp.BasisHeat, kWh/day
Retort process water reheat85 → 110 °C12 cycles × 2,000 L returned to storage drum697
Product and can come-up65 → 110 °C12 cycles × 1,000 kg product, 10% for can and basket metal594
Can and jar washer60 °C6,000 L/day, 30 → 60 °C209
Storage and pipework standing losses–about 5%75
Total useful heat1,575

Averaged over 18 running hours, the heat pumps need about 87 kW.

03P&ID

L-101 · Hot primary · 120 °CTT103L-102 · Return · ~90 °CY-STRP-101AP-101Bduty / standbyEXP-101FS101HP-101…104SE-WWUHT-27 · 27 kWP-100SRC-100retort cooling-waterreturnheat source ~55 °CWater-sourceTK-1013,500 L120 °CinsulatedventTT101TT102LT101softenermake-up waterVFDP-102A/BL-201 · Supply header · 118 °CTCV-201TIC201TK-201Retort storage drum110 °Cdrum return 85 °Cto retort 110 °CTCV-202TIC202PHE-202Can & jar washer60 °CL-202 · Return header · ~90 °CNCB-001 existing FO boilerstandby / top-up onlyhot supplyreturnsignalsource waterpumpvalvenormally closedINDICATIVE P&ID · NOT FOR CONSTRUCTIONAN-011 · Rev 0 · Sunniva Encon LLP

Tags: HP heat pump, TK tank, SG steam generator, P pump, PHE plate heat exchanger, TCV temperature control valve, TIC temperature indicating controller (panel), TT temperature transmitter, MT moisture transmitter, PT pressure transmitter, LT level transmitter, FS flow switch, NC normally closed. Process fluids are heated through their own exchanger, coil or jacket.

04Solution

System description

  • 4 × SE-WWUHT-27 (108 kW total) (SE-WWUHT water-source, R245fa) delivering 120 °C, covering the day's 1,575 kWh in about 14.6 running hours.
  • A 3,500 L insulated storage tank decouples the heat pumps from the process peaks.
  • Heat source: retort cooling-water return at about 55 °C. Cooling the retort water return reduces cooling tower load and can shorten the retort cooling step.
  • The furnace-oil fired steam boiler stays connected behind a normally closed valve as standby.
  • Retort cooling water is collected in an insulated tank at about 55 °C and used as the heat pump source.
  • The heat pump heats the retort storage drums to about 110 °C between cycles through a coil or external exchanger.
  • The existing steam supply brings each retort from 110 °C to the sterilising temperature. This shortens the steam step and lowers peaks.
  • The can and jar washer runs from the same hot-water loop.

Selected equipment

ModelSE-WWUHT-27 × 4
Heating capacity27 kW each, 108 kW total
COP2.93 at the data sheet's rated condition (60/55 °C source water)
Power inputabout 36.8 kW total at rated conditions
Ratingwater or steam to 120 °C, R245fa
Supply temperature120 °C
Storage3,500 L insulated tank

Ratings from the Sunniva TDS 2026 data sheets.

Control philosophy

TT-101 at the tank top starts the heat pump below 112 °C and stops it at 120 °C. TIC-201 heats each storage drum to 110 °C between cycles in a set order. The retort controller and its steam valve keep full control of the sterilisation step. If the tank falls below 105 °C, drums are topped up with steam as before.

05Energy saving and ROI

Change any input to match a customer's site. Defaults are typical Indian prices for October 2026. The installed cost is a placeholder; replace it with the actual quotation.

Plant
Existing heating
Heat pump
Annual saving–energy + O&M
Simple payback––
Purchased energy––
10-year net gain–after paying for the system
ExistingHeat pump
Daily consumption––
Annual energy cost––
Cost per tonne of product––
CO₂ per year––
Cumulative cash position, years 0–10

06Benefits

Lower steam peaks

Retorts start from preheated water, so the boiler sees smaller, shorter peaks.

Shorter cycles

Less come-up time can allow more cycles per day.

Cooling water reused

Heat from cooling each batch preheats the next one.

Lower energy cost

Each kWh of electricity delivers about 2.9 kWh of heat at the required temperature, against well under one kWh of useful heat per kWh of fuel burnt.

No flame on site

No burner, flue or fuel tank for this duty, and no fuel deliveries to schedule.

Built-in redundancy

Several machines share the load. If one is serviced, the others and the storage carry most of the day, with the existing heater in reserve.

07Engineering pointers

Site data to collect

  • Number of retorts, type and cycles per day
  • Product load per cycle and fill temperature
  • Storage drum volume and return temperature
  • Cooling water volume and outlet temperature
  • Steam use per cycle
  • Present fuel or electricity use and monthly bill
  • Sanctioned electrical load and spare capacity
  • Space for the heat pumps and storage, with service access

Design notes

  • Scheduled process unchanged. The validated sterilisation step stays on steam with its existing controls. The heat pump only preheats.
  • Pressure rating. Water at 110–120 °C needs a loop held above about 2.5 bar(g). Check the drum and coil pressure ratings.
  • Cooling water hygiene. Retort cooling water must stay chlorinated. Use a closed exchanger so heat pump water never mixes with it.
  • Electrical. About 37 kW of heat pump input at rated conditions, plus pumps and fans. Check spare sanctioned load before ordering.
  • Source stream. The source must give up roughly two-thirds of the heat delivered. Confirm its flow and temperature over a full production day, and filter it before the evaporator.
  • Water quality. Scale forms quickly above 60 °C. Use softened make-up and keep the heat pump loop closed, with process fluids on the far side of an exchanger or coil.