Technical Data Sheet · Domestic Split Heat Pump Water Heater
SE-AH … S Series · Domestic Split

SE-AH-5|300S

Split heat pump water heater: compressor and fan outdoors, the 300 L enamel-lined cylinder indoors, only refrigerant between them. Hot water to 55 °C on the heat pump, 75 °C with the heater. R134a, single-phase.

Sunniva SE-AH-5|300S split heat pump water heater — cylinder and outdoor unit
Heating capacity
5kW
Rated, heat pump
COP
4.17
Rated
Storage
300L
Enamelled steel cylinder
Hot water output
107.5L/h
15 → 55 °C, heat pump alone (derived)

Performance

Rated figures, and what they mean in litres
Rated dutyheat pump mode
Heating capacity
5,000W
Input power
1,200W
COP
4.17
Hot waterderived
Output, 15 → 55 °C
107.5L/h
Full tank, 15 → 55 °C
≈ 2.8h
Temperature rise
40K
Maximumfor the electrician
Max input power
1,780W
Max current
8.2A
Back-up heater
2kW

Technical specifications

SE-AH-5|300S
Technical specifications for SE-AH-5|300S
ParameterUnitSpecification
Outdoor unit
Heating capacityW5,000
Rated input powerW1,200
COP—4.17
Maximum input powerW1,780
Maximum currentA8.2
Power supply—220 V / 1 Ph / 50 Hz
Refrigerant—R134a
Compressor—Highly, rotary
Noise leveldB(A)52
Ingress protection—IPX4
Ambient operating range°C−5 to 43
Dimensions (L × W × H)mm765 × 260 × 530
Weightkg34
Cylinder
Storage volumeL300
Shellmm2 enamelling-grade steel
Lining—Vitreous glass enamel, 0.3–0.5 mm
Heat exchanger—Micro-channel, aluminium alloy, wrapped round the outside of the tank under the insulation
Electric back-up heaterkW2
Rated working pressureMPa0.7
Inlet / outlet / drain—DN 20
Insulation (polyurethane)mm50
Standing loss over 24 hK< 6
Size (ø × H)mm560 × 1805
Weight, emptykg90
Fittings—Magnesium anode, pressure relief valve
Water temperature°C55 on the heat pump · 75 with the heater
Controller & warranty
Controller—Intelligent wired controller — shows water temperature, switches the heater; 5 m lead
Interconnecting pipe—3 m copper, standard
Warranty—2 years heat pump · 5 years cylinder

Rated figures

  • Heating capacity, input power and COP are the manufacturer’s rated figures; the source does not name the ambient they were measured at, so they are published as rated values. Ask us before sizing to a cold-weather duty.
  • Derived: hot water output is for a 40 K rise (15 → 55 °C) — heating capacity × 0.86 ÷ output gives exactly 40 K. Full-tank time = volume ÷ output.

Installation requirement

  • Dedicated single-phase supply on its own MCB, sized by a licensed electrician for the 8.2 A maximum current, plus the 2 kW heater if on the same circuit.
  • 3 m of copper interconnecting pipe is supplied; tell us before ordering if the run or height difference is longer.
  • Fit the pressure relief valve supplied and pipe its discharge to a drain.

Site installation schematic

Outdoor unit outside, cylinder inside — only refrigerant crosses the wall
OUTDOORSINDOORSCOUTDOOR UNITcompressorhot gasliquid returnCYLINDERhot waterto tapscoldmains inpressure reliefvalveMg anodecontroller5 m leadmicro-channel,outside the tankunder insulationback-up heater
Hot gas / hot waterLiquid refrigerant returnCold mains waterController lead
  1. 1Outdoors, heat from the air. The fan draws outdoor air over the coil; the refrigerant picks up its heat even on a cool morning.
  2. 2Compressed and sent in. The compressor raises the refrigerant’s temperature and sends it through the wall as hot gas.
  3. 3Heat into the water. The micro-channel wrapped round the outside of the tank gives that heat to the water through the steel — refrigerant and water never meet.
  4. 4Back out, round again. The cooled liquid returns to the outdoor unit. Nothing but two thin refrigerant lines crosses the wall.

Schematic — not to scale. Mount the outdoor unit where air moves freely; keep the cylinder close to the bathrooms it serves.

Choosing a size

Size on the people and the draw-off
This model
Hot water per person per day40–60 L
Suitsabout 5–7 people
Full tank from cold≈ 2.8 h on the heat pump 15 → 55 °C
Keeps up with≈ 108 L/h of draw-off

Why split

  • The cylinder stands indoors — utility room or loft — while the outdoor unit sits on a balcony or terrace like an air conditioner.
  • No hot water runs through the wall, and a refrigerant leak cannot reach the potable water.
  • The 2 kW heater covers a cold morning or a full house, and takes the tank to 75 °C when wanted.

The range at a glance

SE-AH-5|300S is marked
ModelTank LHeating kWCOPL/h*Full tank h*Heater kWCylinder ø × H mm
SE-AH-4|150S1503.34.10712.11.5500 × 1330
SE-AH-5|200S20054.17107.51.91.5500 × 1680
SE-AH-5|300S30054.17107.52.82560 × 1805
SE-AH-7|400S4007.24.11154.82.62700 × 1590
SE-AH-7|500S5007.24.11154.83.22700 × 1940

* Derived: hot water output for a 15 → 55 °C rise, and the time to heat a full tank through that rise on the heat pump alone. A 100 L model (SE-AH-4|100S) also sells on the price list; no rated data has been issued for it yet.

Installation steps

Follow in order — fill the cylinder before switching on
  1. Place the cylinder on a level floor that takes its filled weight, close to the bathrooms, with access to the anode and heater.
  2. Mount the outdoor unit on a bracket or plinth with free air on the coil face and the fan side, where its noise will not disturb anyone.
  3. Refrigerant lines. Run the copper pair through a sleeved hole in the wall, insulated, without kinks. 3 m is supplied as standard.
  4. Vacuum and open the service valves as the installation manual describes; check the joints for leaks.
  5. Water. Cold mains to the bottom inlet through an isolation valve and non-return valve; hot to the taps from the top outlet.
  6. Relief valve. Fit the supplied valve and pipe its discharge to an open drain — never cap it.
  7. Electrical. Dedicated single-phase supply and MCB; earth bonded; controller lead (5 m) between the cylinder and the unit.
  8. Commission. Fill and vent the cylinder before switching on, set the water temperature, and check the unit runs and the tank heats.

Site checklist

What has to be true before the unit arrives
Site
FloorLevel, and takes ≈ 390 kg filled
Cylinder space560 × 1805 mm, plus room to service the anode and heater
Outdoor unit765 × 260 × 530 mm · 34 kg, bracket or plinth
Distance3 m of refrigerant pipe standard — ask for longer
Supply220 V single-phase, 8.2 A max + heater
DrainFor the relief valve discharge and the cylinder drain

Protections built in

  • High voltage protection
  • Compressor over-heating protection
  • Hot water over-heating protection
  • Circuit failure protection
  • Refrigerant high pressure protection
  • Refrigerant low pressure protection

Documents & links

Scan with a phone camera, or tap the buttons

Talk to Sunniva

Scan to open a WhatsApp chat

Documentation

Scan to open the latest revision on sunnivaencon.com

Connect & review

Product videos and customer feedback

SE-AH-5|300S · Technical Data Sheet. Specifications are subject to change without prior notice.  ← All Domestic Split models