Sunniva Encon LLP · Application NoteAN-106 · Rev 0 · 23 Oct 2026
Agriculture

Silkworm rearing rooms held at 24–28 °C

How a chawki rearing centre with 400 m² of rearing rooms can hold the warm, humid climate young silkworms need using heat pumps, and what it saves against electric room heaters.

Application#106 Sericulture (silkworm rearing) climate control
Temperature band24–28 °C
Sunniva selection1 × SE-AH-25U
Replaceselectric room heaters

▶Video: Space heating for buildings and farms

V13 · 2–2.5 min
Space heating for buildings and farms

Floor heating, fan coils and air handlers, from homes to poultry sheds

Video coming soon

01Problem statement

  • Young worms are sensitive. Chawki worms need 26–28 °C. Cold rooms slow feeding and moulting and lead to uneven batches.
  • Heaters dry the air. Electric heaters and charcoal braziers dry the room, while young worms need 80–90% relative humidity.
  • Disease from poor control. Swings in temperature and humidity stress worms and encourage grasserie and muscardine.
  • Electric heating is expensive heat. Resistance heaters turn one kWh of electricity into one kWh of heat, at the full commercial tariff. A heat pump moves two to four kWh of heat for the same unit.
  • Large connected load. Heater banks take a big share of the sanctioned load and push up maximum-demand charges.

02Use case

The reference centre rears young-age (chawki) silkworms for farmers covering about 1,000 acres of mulberry. It has four 100 m² rearing rooms that must stay at 26–28 °C and 80–90% relative humidity, including cool winter nights.

Heat userProcess temp.BasisHeat, kWh/day
Rearing room heatingRooms 26–28 °C600 m² envelope × 2 W/m²K × 12 K × 16 h230
Fresh-air heatingSupply air 27 °C1,000 m³/h × 1.2 kg/m³ × 1.005 kJ/kgK × 12 K = 4 kW × 24 h96
Tray and equipment disinfection washing60 °C1,000 L/day, 25 → 60 °C41
Storage and pipework standing losses–about 5%18
Total useful heat385

Averaged over 18 running hours, the heat pumps need about 21 kW.

03P&ID

L-101 · Hot primary · 45 °CTT103L-102 · Return · ~34 °CY-STRP-101AP-101Bduty / standbyEXP-101FS101HP-101SE-AH-25U · 25 kWAir-source, outdoorTK-1011,000 L45 °CinsulatedventTT101TT102LT101softenermake-up waterVFDP-102A/BL-201 · Supply header · 43 °CTCV-201TIC201FCU-201Rearing room FCUs27 °C roomsreturn 38 °Csupply 45 °CTCV-202TIC202AHU-202Fresh-air unit27 °C airTCV-203TIC203DR-203Disinfection wash45 °CL-202 · Return header · ~34 °CNCB-001 existing electric heatersstandby / top-up onlyhot supplyreturnsignalpumpvalvenormally closedINDICATIVE P&ID · NOT FOR CONSTRUCTIONAN-106 · Rev 0 · Sunniva Encon LLP

Tags: HP heat pump, TK tank, SG steam generator, P pump, PHE plate heat exchanger, TCV temperature control valve, TIC temperature indicating controller (panel), TT temperature transmitter, MT moisture transmitter, PT pressure transmitter, LT level transmitter, FS flow switch, NC normally closed. Process fluids are heated through their own exchanger, coil or jacket.

04Solution

System description

  • 1 × SE-AH-25U (25 kW) (SE-AH air-source heat pump) delivering 45 °C, covering the day's 385 kWh in about 15.4 running hours.
  • A 1,000 L insulated storage tank decouples the heat pumps from the process peaks.
  • The electric room heaters stays connected behind a normally closed valve as standby.
  • Low-speed fan coils in each rearing room give even warmth without drafts across the rearing trays.
  • A small fresh-air unit preheats ventilation air so worms get fresh air without a temperature drop.
  • Humidity is topped up with a separate humidifier, controlled from the same room sensors.
  • Hot water from the tank also supports washing of trays and equipment between batches.

Selected equipment

ModelSE-AH-25U × 1
Heating capacity25 kW each, 25 kW total
COP4.2 at A20 °C / W50 °C (data sheet T1)
Power inputabout 6.0 kW total at rated conditions
Ratingrated 55 °C, 60 °C maximum, R410A
Supply temperature45 °C
Storage1,000 L insulated tank

Ratings from the Sunniva TDS 2026 data sheets.

Control philosophy

TT-101 at the top of the tank starts the heat pumps below 40 °C and stops them at 45 °C. TIC-201 in each room holds 27 °C by modulating the fan coil valve, and a humidity sensor drives the humidifier to 85%. The existing electric heaters stay as standby.

05Energy saving and ROI

Change any input to match a customer's site. Defaults are typical Indian prices for October 2026. The installed cost is a placeholder; replace it with the actual quotation.

Plant
Existing heating
Heat pump
Annual saving–energy + O&M
Simple payback––
Purchased energy––
10-year net gain–after paying for the system
ExistingHeat pump
Daily consumption––
Annual energy cost––
CO₂ per year––
Cumulative cash position, years 0–10

06Benefits

Uniform batches

Steady temperature and humidity give even feeding and moulting across the batch.

No smoke in rearing rooms

No charcoal or kerosene heaters, which can harm worms and workers.

Lower power bill

Heat pumps use about a third of the electricity of resistance heaters for the same warmth.

Lower energy cost

Each kWh of electricity delivers about 4.2 kWh of heat at the required temperature, against well under one kWh of useful heat per kWh of fuel burnt.

Smaller electrical load

The heat pump draws roughly 1/4.2 of the power of the heaters it replaces, which frees sanctioned load and cuts demand charges.

Solar-ready

Running hours can be placed in daylight so rooftop solar supplies much of the electricity, which also cuts CO₂ further.

07Engineering pointers

Site data to collect

  • Room sizes, construction and insulation
  • Rearing calendar and target temperature and humidity by instar
  • Lowest winter temperatures at site
  • Current heater ratings and hours
  • Ventilation arrangement
  • Present fuel or electricity use and monthly bill
  • Sanctioned electrical load and spare capacity
  • Space for the heat pumps and storage, with service access
  • Winter minimum ambient at site

Design notes

  • Air movement. Keep air speed over trays low. Use fan coils on low speed and direct air away from the trays.
  • Disinfection. Rooms are disinfected with chlorine or formalin between batches. Protect fan coils and controls and switch them off during fumigation.
  • Insulation. Seal and insulate rooms first. Poorly sealed rooms make humidity hard to hold.
  • Electrical. About 6 kW of heat pump input at rated conditions, plus pumps and fans. Check spare sanctioned load before ordering.
  • Winter output. Air-source output falls in cold weather: about two-thirds of rated capacity at 5 °C ambient. Size on the coldest design day for northern sites.

Service and warranty

Sunniva has supplied 5,000+ heat pumps since 2012, with nine service technicians across India, including remote sites such as Leh. All components carry a one-year warranty.